Advanced Water Company
No Items in Cart
 
 
 
Select product by Manufacturer
Select product by Type
Cylinder Spares by Manufacturer
Water Heater Spares by Manufacturer
 

 

Section Menu

By Manufacturer
»
Altecnic
»
Watts Industries

Watts Industries - GS Leak Detectors

Type GS1 0945200 LPG 230V Electronic Gas Leak Detector Type GS1 0945200 LPG 230V Electronic Gas Leak Detector
  • Electronic gas leak detector unit (sensor inside the unit) with acoustic and luminous alarm
  • To be connected to one or more normally closed gas solenoid valves with manual resetting (EVO, EV) or normally open (MSVO, MSVG).
  • Power consumption: 4 W.
  • Relay contact load capacity: 550 VA. Calibration in the range 5-20% LIE.
  • Operating temperature: - 10°C / + 50°C. Spray- and dust-proof transformer and relays: IP67.
  • Protection class of the detector unit: IP42. Thermal compensation for the sensor.
  • Fault: when a critical fault occurs on the sensor or main components, a luminous signal is given.
  • IMQ approved (only GS1 for natural gas).
  • According to EEC 89/336, EEC 73/23, Min. Circular 27/7/1994 N° 161892.
List Price:£89.35+VAT
Saving:£17.87+VAT
Our Price:£71.48+VAT
List Price:£107.22
Saving:£21.44
Our Price:£85.78
Qty:
Type GS3 0940300 Natural Gas 230V Electronic Gas Leak Detector Type GS3 0940300 Natural Gas 230V Electronic Gas Leak Detector
  • Electronic gas leak detector unit (sensor inside the unit) with acoustic and luminous alarm
  • To be connected to one or more normally closed gas solenoid valves (EVO, EV) or normally open (MSVO, MSVG).
  • The gas detector can function as a single unit or with 2 remote units UR (2 units for natural gas or 2 units for LGP).
  • Other technical characteristics like GS1.
  • According to EEC 89/336, EEC 73/23, Min. Circular 27/7/1994 N° 161892.
List Price:£103.47+VAT
Saving:£20.70+VAT
Our Price:£82.77+VAT
List Price:£124.16
Saving:£24.84
Our Price:£99.32
Qty:
Type GS3 0945300 LPG 230V Electronic Gas Leak Detector Type GS3 0945300 LPG 230V Electronic Gas Leak Detector
  • Electronic gas leak detector unit (sensor inside the unit) with acoustic and luminous alarm
  • To be connected to one or more normally closed gas solenoid valves (EVO, EV) or normally open (MSVO, MSVG).
  • The gas detector can function as a single unit or with 2 remote units UR (2 units for natural gas or 2 units for LGP).
  • Other technical characteristics like GS1.
  • According to EEC 89/336, EEC 73/23, Min. Circular 27/7/1994 N° 161892.
List Price:£102.93+VAT
Saving:£20.59+VAT
Our Price:£82.34+VAT
List Price:£123.52
Saving:£24.71
Our Price:£98.81
Qty:
Type UR 0940350 Natural Gas Electronic Gas leak Detector Type UR 0940350 Natural Gas Electronic Gas leak Detector
  • Gas leak detector unit to be connected to unit GS3. Power supply taken from unit GS3: 12Vcc.
  • Calibration in the range; 5-20% LIE. Power consumption: 0.5 W.
  • Operating temperature: - 10°C / + 50°C. Protection class: IP42.
  • According to EEC 89/336, EEC 73/23.
List Price:£50.16+VAT
Saving:£10.03+VAT
Our Price:£40.13+VAT
List Price:£60.19
Saving:£12.03
Our Price:£48.16
Qty:
Type UR 0945350 LPG Electronic Gas leak Detector Type UR 0945350 LPG Electronic Gas leak Detector
  • Gas leak detector unit to be connected to unit GS3. Power supply taken from unit GS3: 12Vcc.
  • Calibration in the range; 5-20% LIE. Power consumption: 0.5 W.
  • Operating temperature: - 10°C / + 50°C. Protection class: IP42.
  • According to EEC 89/336, EEC 73/23.
List Price:£49.68+VAT
Saving:£9.95+VAT
Our Price:£39.73+VAT
List Price:£59.62
Saving:£11.94
Our Price:£47.68
Qty:
Type GSA3 0940400 Natural Gas 230V Electronic Gas Leak Detector Type GSA3 0940400 Natural Gas 230V Electronic Gas Leak Detector
  • Electronic gas leak detector unit (sensor inside the unit) with acoustic and luminous alarm
  • Plus relay for commanding one or more gas solenoid valves normally closed (EVO, EV) or normally open (MSVO, MSVG).
  • The gas detector can function as a single unit or with 2 remote units URA or CIVR.
  • Power consumption: 4 W + 0.5 W for URA, CIVR.
  • Calibration in the range: 5-20% LIE. Relay contact load capacity: 550 VA.
  • Operating temperature: - 10°C / + 50°C. Spray- and dust-proof transformer and relays: IP67.
  • System reset button. Protection class: IP42. Thermal compensation for the sensor.
  • GENERAL SAFETY GUARANTEE
  • The GSA units are provided with an electronic self-diagnostics circuit continuously monitoring the unit for correct operation.
  • Any fault is warned through an acoustic and light (yellow LED) signal while the gas line solenoid valve is closed automatically
  • According to EEC 89/336, EEC 73/23.
List Price:£134.95+VAT
Saving:£27.00+VAT
Our Price:£107.95+VAT
List Price:£161.94
Saving:£32.40
Our Price:£129.54
Qty:
Type GSA3 0945400 LPG 230V Electronic Gas Leak Detector Type GSA3 0945400 LPG 230V Electronic Gas Leak Detector
  • Electronic gas leak detector unit (sensor inside the unit) with acoustic and luminous alarm
  • Plus relay for commanding one or more gas solenoid valves normally closed (EVO, EV) or normally open (MSVO, MSVG).
  • The gas detector can function as a single unit or with 2 remote units URA or CIVR.
  • Power consumption: 4 W + 0.5 W for URA, CIVR.
  • Calibration in the range: 5-20% LIE. Relay contact load capacity: 550 VA.
  • Operating temperature: - 10°C / + 50°C. Spray- and dust-proof transformer and relays: IP67.
  • System reset button. Protection class: IP42. Thermal compensation for the sensor.
  • GENERAL SAFETY GUARANTEE
  • The GSA units are provided with an electronic self-diagnostics circuit continuously monitoring the unit for correct operation.
  • Any fault is warned through an acoustic and light (yellow LED) signal while the gas line solenoid valve is closed automatically
  • According to EEC 89/336, EEC 73/23.
List Price:£134.38+VAT
Saving:£26.88+VAT
Our Price:£107.50+VAT
List Price:£161.26
Saving:£32.26
Our Price:£129.00
Qty:
Type CIVR 0940550 Natural Gas Central Unit For Installation In Zones With Explosion Risk Type CIVR 0940550 Natural Gas Central Unit For Installation In Zones With Explosion Risk
  • Central unit for installation in zones with explosion risk (e.g. boilers > 35 kw), to be connected to CIVIC2, CIVIC6 or GSA3 for detecting presence of gas.
  • The sensor, housed in an exproof metal case, with sintered drain, allows installation of remote unit CIVR in zones classified as hazardous (CEI64/2).
  • Power supply from CIVIC2 or CIVIC6 or GSA3 (12V).
  • Protection class (unit): IP54. Unit with intrinsic safety. Calibration in the range: 5/20% LIE.
  • Operating temperature: - 10°C / + 50°C. Humidity: 0 - 80% (appreciable variation of calibration could occur at higher percentage humidity).
  • Temperature class T3 (max. surface temperature less than 200°C).
  • According to EEC 89/336, EEC 73/23.
List Price:£83.11+VAT
Saving:£16.62+VAT
Our Price:£66.49+VAT
List Price:£99.73
Saving:£19.94
Our Price:£79.79
Qty:
Type CIVR 0945550 LPG Central Unit For Installation In Zones With Explosion Risk Type CIVR 0945550 LPG Central Unit For Installation In Zones With Explosion Risk
  • Central unit for installation in zones with explosion risk (e.g. boilers > 35 kw), to be connected to CIVIC2, CIVIC6 or GSA3 for detecting presence of gas.
  • The sensor, housed in an exproof metal case, with sintered drain, allows installation of remote unit CIVR in zones classified as hazardous (CEI64/2).
  • Power supply from CIVIC2 or CIVIC6 or GSA3 (12V).
  • Protection class (unit): IP54. Unit with intrinsic safety. Calibration in the range: 5/20% LIE.
  • Operating temperature: - 10°C / + 50°C. Humidity: 0 - 80% (appreciable variation of calibration could occur at higher percentage humidity).
  • Temperature class T3 (max. surface temperature less than 200°C).
  • According to EEC 89/336, EEC 73/23.
List Price:£82.60+VAT
Saving:£16.52+VAT
Our Price:£66.08+VAT
List Price:£99.12
Saving:£19.82
Our Price:£79.30
Qty:
Type CIVIC2 0940502 230V Central Unit For Installation In Zones With Explosion Risk Type CIVIC2 0940502 230V Central Unit For Installation In Zones With Explosion Risk
  • Central unit for installation in zones with explosion risk (e.g. boilers > 35 kw) with alarm and command for solenoid valve normally closed (EVO, EV) or normally open (MSVO or MSVG) and remote alarm (siren, telephone dialler, etc.).
  • Provision for connecting up to 2 remote sensors CIVR or URA for natural gas or LPG, also of different type (CIVR for natural gas and LPG or URA for natural gas and LPG).
  • Relay contact load capacity: 550 VA. Operating temperature: - 10°C / + 50°C.
  • Spray- and dust-proof transformer and relays: IP67. Protection class (unit): IP55.
  • Temperature class T3 (max. surface temperature less than 200°C).
  • Unit with intrinsic safety. Buzzer 85 db (A) at 1 m.
  • Indicators :
  • - Green POWER LED signals correct power supply and running.
    - Red GAS LED + buzzer signals, for each remote unit CIVR connected, a gas leak or fault on the electronic circuits (self-diagnostics function).
  • According to EEC 73/23, EEC 89/336.
List Price:£141.05+VAT
Saving:£28.21+VAT
Our Price:£112.84+VAT
List Price:£169.26
Saving:£33.85
Our Price:£135.41
Qty:
Type CIVIC6 0940506 230V Central Unit For Installation In Electrical Cabinet Type CIVIC6 0940506 230V Central Unit For Installation In Electrical Cabinet
  • Central unit for installation in electrical cabinet (omega guide DIN EN50022 35 mm), with alarm and command for solenoid valve normally closed (EVO, EV) or normally open (MSVO or MSVG) and remote alarm (siren, telephone dialler, etc.).
  • Provision for connecting up to 6 remote sensors CIVR or URA for natural gas or LPG, also of different type (CIVR for natural gas and LPG or URA for natural gas and LPG).
  • Relay contact load capacity: 550 VA. Operating temperature: - 10°C / + 50°C.
  • Spray- and dust-proof transformer and relays: IP67. Protection class (unit): IP20.
  • System reset button. Buzzer 85 db (A) at 1 m.
  • Indicators :
  • - Green POWER LED signals correct power supply and running.
    - Red GAS LED + buzzer signals, for each remote unit CIVR connected, a gas leak or fault on the electronic circuits (self-diagnostics function).
  • According to EEC 73/23, EEC 89/336.
List Price:£238.56+VAT
Saving:£47.71+VAT
Our Price:£190.85+VAT
List Price:£286.27
Saving:£57.25
Our Price:£229.02
Qty:
Type CIVR 0940550 Natural Gas Central Unit For Installation In Zones With Explosion Risk Type CIVR 0940550 Natural Gas Central Unit For Installation In Zones With Explosion Risk
  • Central unit for installation in zones with explosion risk (e.g. boilers > 35 kw), to be connected to CIVIC2, CIVIC6 or GSA3 for detecting presence of gas.
  • The sensor, housed in an exproof metal case, with sintered drain, allows installation of remote unit CIVR in zones classified as hazardous (CEI64/2).
  • Power supply from CIVIC2 or CIVIC6 or GSA3 (12V).
  • Protection class (unit): IP54. Unit with intrinsic safety. Calibration in the range: 5/20% LIE.
  • Operating temperature: - 10°C / + 50°C. Humidity: 0 - 80% (appreciable variation of calibration could occur at higher percentage humidity).
  • Temperature class T3 (max. surface temperature less than 200°C).
  • According to EEC 89/336, EEC 73/23.
List Price:£162.30+VAT
Saving:£32.46+VAT
Our Price:£129.84+VAT
List Price:£194.76
Saving:£38.95
Our Price:£155.81
Qty:
Type CIVR 0945550 LPG Central Unit For Installation In Zones With Explosion Risk Type CIVR 0945550 LPG Central Unit For Installation In Zones With Explosion Risk
  • Central unit for installation in zones with explosion risk (e.g. boilers > 35 kw), to be connected to CIVIC2, CIVIC6 or GSA3 for detecting presence of gas.
  • The sensor, housed in an exproof metal case, with sintered drain, allows installation of remote unit CIVR in zones classified as hazardous (CEI64/2).
  • Power supply from CIVIC2 or CIVIC6 or GSA3 (12V).
  • Protection class (unit): IP54. Unit with intrinsic safety. Calibration in the range: 5/20% LIE.
  • Operating temperature: - 10°C / + 50°C. Humidity: 0 - 80% (appreciable variation of calibration could occur at higher percentage humidity).
  • Temperature class T3 (max. surface temperature less than 200°C).
  • According to EEC 89/336, EEC 73/23.
List Price:£161.79+VAT
Saving:£32.35+VAT
Our Price:£129.44+VAT
List Price:£194.15
Saving:£38.82
Our Price:£155.33
Qty:
Type LAG 0190100 230V Leak Indicator Systems For Double Chamber Tanks For Storage Of Inflammable Liquids Type LAG 0190100 230V Leak Indicator Systems For Double Chamber Tanks For Storage Of Inflammable Liquids
  • Leak indicator systems for double chamber tanks for storage of inflammable liquids.
  • Complete with electronic indicator unit LAGN, lever indicator BAE10.
  • Power consumption: 10VA.
  • Extra alarm relay: 5A - 250 V.
  • For mounting the installation system use the complete set of accessories series LAGMS.
  • According to DIN6608, EEC 89/336, EEC 73/23.
  • Approval ATEX 94/9/EEC.
List Price:£222.51+VAT
Saving:£44.50+VAT
Our Price:£178.01+VAT
List Price:£267.01
Saving:£53.40
Our Price:£213.61
Qty:
 
 
Advanced Water Company
Unit D5 Enterprise Centre
Off Enterprise Way
Vale Park, Evesham
Worcestershire. WR11 1GS